Products / Non Compensated Chokes (CLTP)

Non Compensated Chokes (CLTP)

Series: CLTP – 10, 14, 15, 18, 20, 22, 23, 28, 33

Chokes in vertical and Horizontal version enable space economising, compact printed circuit board assembly.
All choke types comply with the guidelines of EN 60938-2.
In combination with suitable capacitors, high quality interference suppression filters against parasite interference influences are achieved. Main application fields are: general purpose filtering of parasite disturbance factors above all with symmetric interferences e.g. in frequency converters, switch mode power supplies, automotive electronics etc.
Frequently they are also used in combination with current compensated interference suppression chokes. Optimum adaptation of core materials and technical design guarantee the best possible compliance with the world-wide high requirements with the smallest volume.
The simple construction enables high performance parameters with the smallest heat development and an optimum price-performance ratio.
Four closed housings are complemented by one version in open structure.

Specification Sheet

Nominal current : 0.63 ÷ 4A
Inductance at IN = 0 : 27 ÷ 1000 μH
Inductance drop at IN : approx. 30%
Max. operating voltage : UR 600 VDC
Operating frequency : up to 20 kHz
Test voltage : 2 kVAc /2s, wdg. to ambient
Climatic class : 40/125/21 as per IEC 60068-1
Inflammability : UL 94 V-0
Definitions

Definitions

N turn ratio or voltage ratio between primary and secondary windings.
∫Udt voltage-time area (Vμs)
This is the product of impulse height and pulse width measured at half impulse height.
tr Pulse rise time (μs)
This time is measured from 10% ÷ 90% of the pulse height.
If Firing current (A)
Max. available pulse current.
LP Primary inductance (mH)
Measured as per EN 60938 ( signal 0.1mA, tolerance -30 +50%).
CC Coupling capacity (pF)
Measured between primary and secondary winding.
Is heavily dependent on the winding structure.
UR Maximum operating voltage (V)
UP Test voltage (kV)
Measured between primary and secondary winding
Also dependent on the winding structure.
Measurement 100% in the final test (up to 3.5 kV AC for 2 seconds).
UG Glow discharge voltage (V)
Determines the life expectancy of the IT's in operation with excessive operating voltage. At least 50% higher than the max. operating voltage.
Pd Maximum power loss at 50°C ambient temperature.

Filter by:

  • IN [A]
    (@ ϑa 70°C)
  • LN [μH]
    ±15%
  • SMD

Showing all 25 results

CLTP-6110-01C5
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6110-01C51472700.316
CLTP-6110-D6D10.631006000.39
CLTP-6114-02C5
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6114-01D211802450.33
CLTP-6114-02C5247600.311
CLTP-6114-D6D50.634707500.31.5
CLTP-6120-03C3
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6120-02D11.51201400.33.5
CLTP-6120-03C33.1527300.316
CLTP-6120-D6D70.636807000.30.9
CLTP-6122-04C7
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6122-0101110006500.71.6
CLTP-6122-02D322701700.72
CLTP-6122-04C7468350.69
CLTP-6133-04D1
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6133-02D524702901.22
CLTP-6133-03D23.15180900.94
CLTP-6133-04D14120520.96.5
CLTP-6115-01D2
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6115-01D211802450.33
CLTP-6115-D6D50.634707500.31.5
CLTP-6118-03C3
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6118-02D11.51201400.33.5
CLTP-6118-03C33.1527300.316
CLTP-6118-D6D70.636807000.30.9
CLTP-6123-04C7
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6123-0101110006500.71.6
CLTP-6123-02D322701700.72
CLTP-6123-04C7468350.69
CLTP-6128-04D1
TypeIN [A]
(@ ϑa 70°C)
LN [μH]
±15%
RCu [mΩ]
±10%
Ploss [W]fres [MHZ]
approx.
Datasheet
CLTP-6128-02D323301700.72
CLTP-6128-03D23.15150700.75
CLTP-6128-04D14100420.76
CLTP-6110-01C5
Type
CLTP-6110-01C5
CLTP-6110-D6D1
CLTP-6114-02C5
Type
CLTP-6114-01D2
CLTP-6114-02C5
CLTP-6114-D6D5
CLTP-6120-03C3
Type
CLTP-6120-02D1
CLTP-6120-03C3
CLTP-6120-D6D7
CLTP-6122-04C7
Type
CLTP-6122-0101
CLTP-6122-02D3
CLTP-6122-04C7
CLTP-6133-04D1
Type
CLTP-6133-02D5
CLTP-6133-03D2
CLTP-6133-04D1
CLTP-6115-01D2
Type
CLTP-6115-01D2
CLTP-6115-D6D5
CLTP-6118-03C3
Type
CLTP-6118-02D1
CLTP-6118-03C3
CLTP-6118-D6D7
CLTP-6123-04C7
Type
CLTP-6123-0101
CLTP-6123-02D3
CLTP-6123-04C7
CLTP-6128-04D1
Type
CLTP-6128-02D3
CLTP-6128-03D2
CLTP-6128-04D1
Key
  • Current derating over 70°C: I = IN • √(125 - ϑa) /55
  • Lo measured according to EN 60938-2
  • RCu measured at 25°C ambient temperature